A BRIEF OVERVIEW OF CAVITY-ENHANCED RAMAN SPECTROSCOPY FOR GAS DETECTION AND ANALYSIS

Mualliflar

  • Murod Malikov Associate professor at the Alfraganus University Muallif

;

Raman spectroscopy, gas detection, cavity enhancement.

Abstrak

The gas sensor market is predominantly dominated by electrochemical, semiconductor, and non-dispersive infrared absorption (NDIR)-based optical sensors. While these technologies offer a broad range of detectable gases, identifying unknown gas mixtures remains a challenge, as sensor selection must be predetermined to minimize cross-talk. As an optical alternative, Raman spectroscopy provides a versatile solution, requiring no prior knowledge and covering nearly all gas compounds. However, its application is limited by a low quantum yield due to the weak scattering cross-section of gases. To address this limitation, various enhancement techniques have been explored, with cavity-enhanced Raman spectroscopy emerging as a promising approach. By utilizing optical cavities, this technique increases laser beam power and extends analyte interaction lengths, enabling improved detection while allowing for cost-effective instrumentation. This review examines the advancements in cavity-enhanced Raman spectroscopy, focusing on research trends, typical experimental setups, and the achieved spectral resolutions.

Iqtiboslar

Gebicki, J. Application of electrochemical sensors and sensor matrixes for measurement of odorous chemical compounds. TrAC Trends Anal. Chem. 2016, 77, 1–13. [Google Scholar] [CrossRef]

Wilson, A.D.; Baietto, M. Applications and advances in electronic-nose technologies. Sensors 2009, 9, 5099–5148. [Google Scholar] [CrossRef] [PubMed]

Boeker, P. On ‘electronic nose’methodology. Sen. Actuators Chem. 2014, 204, 2–17. [Google Scholar] [CrossRef]

Munoz, R.; Sivret, E.C.; Parcsi, G.; Lebrero, R.; Wang, X.; Suffet, I.M.; Stuetz, R.M. Monitoring techniques for odour abatement assessment. Water Res. 2010, 44, 5129–5149. [Google Scholar] [CrossRef]

Dinh, T.V.; Choi, I.Y.; Son, Y.S.; Kim, J.C. A review on non-dispersive infrared gas sensors: Improvement of sensor detection limit and interference correction. Sens. Actuators B Chem. 2016, 231, 529–538. [Google Scholar] [CrossRef]

Hummelga, C.; Bryntse, I.; Bryzgalov, M.; Martin, H.; Norén, M.; Rödjega, H. Low-cost NDIR based sensor platform for sub-ppm gas detection. Urban Clim. 2015, 14, 342–350. [Google Scholar] [CrossRef]

Gibson, D.; MacGregor, C. A Novel Solid State Non-Dispersive Infrared CO2 Gas Sensor Compatible with Wireless and Portable Deployment. Sensors 2013, 13, 7079–7103. [Google Scholar] [CrossRef] [Green Version]

Mendes, L.B.; Ogink, N.W.M.; Edouard, N.; Van Dooren, H.J.C.; Tinôco, I.D.F.F.; Mosquera, J. NDIR Gas Sensor for Spatial Monitoring of Carbon Dioxide Concentrations in Naturally Ventilated Livestock Buildings. Sensors 2015, 15, 11239–11257. [Google Scholar] [CrossRef] [Green Version]

Liu, H.; Shi, Y.; Wang, T. Design of a six-gas NDIR gas sensor using an integrated optical gas chamber. Opt. Express 2020, 28, 11451–11462. [Google Scholar] [CrossRef] [PubMed]

Jacquinot, P. New developments in interference spectroscopy. Rep. Prog. Phys. 1960, 23, 267–312. [Google Scholar] [CrossRef]

Nashr qilingan

2025-02-18

Iqtibos keltirish tartibi

A BRIEF OVERVIEW OF CAVITY-ENHANCED RAMAN SPECTROSCOPY FOR GAS DETECTION AND ANALYSIS. (2025). Zamonaviy Dunyoda Innovatsion Tadqiqotlar, 4(6), 38-42. https://in-academy.uz/index.php/ZDIT/article/view/18020